The data, information and descriptions, and the technology described herein are the exclusive intellectual property of Snap-on Climate Solutions S.r.l. and
constitute industrial secrets. Said information is communicated in strict confidentiality; said information may be used only for the purpose for which it is
communicated; said information may not be divulged, communicated, or revealed to third parties and/or reproduced by any means for any reason whatsoever; said
information is protected under applicable Italian competition and industrial property law.
Service manual Cinquecento12 (VA21) [MANUY2V.SB0] ed.1 ver.0.1.doc pag.51 - 09/11/2021
8) Type the filter code and press ENTER to delete the alarm. If the filter code is not
available, call the Service Center:
9) Press ENTER to continue with vacuum check:
10) If leaks are detected the following screen will be displayed:
Check filter tightening and press ESC to restart the vacuum check.
11) After few minutes, if no leaks are detected the following screen will be displayed:
Reset service alarm enter filter code
________
DD/MM/YY XX:XX PM
ENTER
ESC
After changing the filter
Following the user manual,
Press ENTER
to insert the counter reset code
Check leaks with vacuum
STOP
DD/MM/YY XX:XX PM
WARNING!
LEAKS!
Press ESC to exit
DD/MM/YY XX:XX PM
- CHANGE DRYER FILTER
ESC