The data, information and descriptions, and the technology described herein are the exclusive intellectual property of Snap-on Climate Solutions S.r.l. and
constitute industrial secrets. Said information is communicated in strict confidentiality; said information may be used only for the purpose for which it is
communicated; said information may not be divulged, communicated, or revealed to third parties and/or reproduced by any means for any reason whatsoever; said
information is protected under applicable Italian competition and industrial property law.
Service manual Cinquecento12 (VA21) [MANUY2V.SB0] ed.1 ver.0.1.doc pag.73 - 09/11/2021
TEMPERATURE
NOTE: A digital thermometer is required for tank temperature sensor calibration. From
CALIBRATION, select TEMPERATURE, the following screen is displayed:
If you have not changed the sensor or motherboard you can restore the calibration (refer to
RESTORE CALIBRATION paragraph)
Check that the tank temperature probe is disconnected from the tank and so capable of
reading the ambient temperature.
Check that the temperature shown on the display is that also read on the external
thermometer.
If necessary press SET end type the value read on the external thermometer and select
ENTER button; then press ENTER to confirm. Replace the temperature probe on the tank.
Press EXC for record the values.
TANK SENSOR (Min 10, Max 40 °C)
________