Chapter 27
| OAM Commands
ā 863 ā
Command Usage
ā Critical events are vendor-specific and may include various failures, such as
abnormal voltage fluctuations, out-of-range temperature detected, fan failure,
CRC error in flash memory, insufficient memory, or other hardware faults.
ā Dying gasp events are caused by an unrecoverable failure, such as a power
failure or device reset.
Note:
When system power fails, the switch will always send a dying gasp trap
message prior to power down.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam critical-link-event dying-gasp
Console(config-if)#
efm oam
link-monitor frame
This command enables reporting of errored frame link events. Use the no form to
disable this function.
Syntax
[no] efm oam link-monitor frame
Default Setting
Enabled
Command Mode
Interface Configuration
Command Usage
ā An errored frame is a frame in which one or more bits are errored.
ā If this feature is enabled and an errored frame link event occurs, the local OAM
entity (this switch) sends an Event Notification OAMPDU.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame
Console(config-if)#