7. Installaon
WARNING: RISK OF CUTTING AND CRUSHING
Risk of cung and cung o by contact with moving parts such as couplings, shas and
rotors. Risk of cung and crushing when reaching into open anges or covers. Do not
operate the vacuum pump with open anges or covers. When installing, rst
mechanically connect the inlets and outlets, close the covers of rotang parts and then
make the electrical connecons. Disconnect the vacuum pump from the power supply
before servicing. Only use trained service personnel.
WARNING: EJECTION OF PARTS
Ejecon of parts through bursng of vacuum system due to excessive pressure caused by
incorrect direcon of rotaon. Pressure build-up in the vacuum system or in vacuum
chambers. Check the direcon of rotaon of the vacuum pumps before each start-up,
aer each motor change and aer each electrical connecon change.
Ejecon of parts through bursng of vacuum system due to excessive pressure, caused by
faulty funcon at the gas inlet into the vacuum system. Pressure build-up in the vacuum
system or inlet lines. Check correct connecon of inlet and outlet anges before
commissioning. The inlet pressure at the sucon port of the vacuum system must not
exceed atmospheric pressure. If seal gas or gas-ballast from pressure vessels is used,
secure the supply in such a way that no overpressure can occur in the vacuum system in
the event of a fault or power interrupon.
WARNING: RISK OF GAS LEAKAGE
The atmospheric sha seal between the gearbox and atmosphere is a PTFE dynamic seal,
which may, under wear-out condions, lead to small leakage of gas. Ensure that purge
gas is supplied connuously to the main pump sha seals to prevent process gas entering
the gearbox which could otherwise leak from the atmospheric sha seal. Leakage of
purge gas to atmosphere should also be considered; ensure the pump is in a well
venlated area.
Only competent persons may install this EDS pump.
Ensure that you comply with all local and naonal safety requirements when you install
the pump.
Do not operate the pump system unless the inlet and outlet are connected to your
piping system.
Disconnect the other components in the pumping system from the electrical supply so
that they cannot be operated accidentally.
Electrical, purge gas and water supplies are all potenally hazardous energy sources.
Before carrying out any maintenance the supply of these sources should be locked and
tagged out.
Ensure that the cooling-air ow through the pump-motor cooling-fan cannot be
obstructed.
Ensure that all electrical cables, purge gas pipelines and cooling-water pipelines are
safely posioned, secured and routed, so that they do not present a trip hazard.
Page 22
A41802880_C - Installaon