7. Installaon
WARNING: RISK OF CUTTING AND CRUSHING
Risk of cung and cung o by contact with moving parts such as couplings, shas and
rotors. Risk of cung and crushing when reaching into open anges or covers. Do not
operate the vacuum pump with open anges or covers. When installing, rst
mechanically connect the inlets and outlets, close the covers of rotang parts and then
make the electrical connecons. Disconnect the vacuum pump from the power supply
before servicing. Only use trained service personnel.
WARNING: EJECTION OF PARTS
Ejecon of parts through bursng of vacuum system due to excessive pressure caused by
incorrect direcon of rotaon. Pressure build-up in the vacuum system or in vacuum
chambers. Check the direcon of rotaon of the vacuum pumps before each start-up,
aer each motor change and aer each electrical connecon change.
Ejecon of parts through bursng of vacuum system due to excessive pressure, caused by
faulty funcon at the gas inlet into the vacuum system. Pressure build-up in the vacuum
system or inlet lines. Check correct connecon of inlet and outlet anges before
commissioning. The inlet pressure at the sucon port of the vacuum system must not
exceed atmospheric pressure. If seal gas or gas-ballast from pressure vessels is used,
secure the supply in such a way that no overpressure can occur in the vacuum system in
the event of a fault or power interrupon.
WARNING: RISK OF GAS LEAKAGE
The atmospheric sha seal between the gearbox and atmosphere is a PTFE dynamic seal,
which may, under wear-out condions, lead to small leakage of gas. Ensure that purge
gas is supplied connuously to the main pump sha seals to prevent process gas entering
the gearbox which could otherwise leak from the atmospheric sha seal. Leakage of
purge gas to atmosphere should also be considered; ensure the pump is in a well
venlated area.
Only competent persons may install this EDS pump.
▪
Ensure that you comply with all local and naonal safety requirements when you install
the pump.
▪
Do not operate the pump system unless the inlet and outlet are connected to your
piping system.
▪
Disconnect the other components in the pumping system from the electrical supply so
that they cannot be operated accidentally.
▪
Electrical, purge gas and water supplies are all potenally hazardous energy sources.
Before carrying out any maintenance the supply of these sources should be locked and
tagged out.
▪
Ensure that the cooling-air ow through the pump-motor cooling-fan cannot be
obstructed.
▪
Ensure that all electrical cables, purge gas pipelines and cooling-water pipelines are
safely posioned, secured and routed, so that they do not present a trip hazard.
Page 22
A41802880_C - Installaon