11. Diagnose a fault
A list of fault condions and their possible causes is provided here to assist in basic
troubleshoong. If you are unable to recfy a fault using this guide, call your supplier or your
nearest Edwards Service Centre for advice.
Fault Pump does not start up
Cause Motor incorrectly connected.
Remedy Connect motor correctly.
Cause Overtemperature switch or motor stator defecve.
Remedy Contact Edwards Service.
Cause Pressure switch is defecve.
Remedy Replace the pressure switch.
Cause Lubricant is too thick.
Remedy Exchange the lubricant or warm up lubricant and pump.
Cause Motor rotor defecve.
Remedy Contact Edwards Service.
Cause Pump has seized: defecve rotors, bearings or toothed gears.
Remedy Contact Edwards Service.
Fault
Pump gets too hot
Cause Cooling-water supply is not sucient.
Remedy Ensure sucient cooling-water supply.
Cause Cooling-water lines are clogged.
Remedy Decalcify cooling-water lines.
Cause Ambient temperature is too high or cooling air ow is obstructed.
Remedy Install the pump at a suitable place or ensure a sucient ow of cooling air.
Cause Pump is operang in the wrong pressure range.
Remedy Check the pressure levels within the system.
Cause Gas temperature is too high.
Remedy Check system.
Cause Clearance between housing and rotors are too small due to contaminaon.
Remedy Clean pumping chamber.
Cause Clearance between housing and rotors are too small due to distoron of the pump.
Remedy
Ax and connect the pump free of tension.
Page 43
A41802880_C - Diagnose a fault