WARNING: HAZARDOUS VOLTAGES
Risk of electric shock. All connecons t
o the interface control must be double
insulated or have equivalent protecon. Do not connect voltages greater than
30 V a.c. or 60 V d.c. to the control/interface connecons.
WARNING: HAZARDOUS VOLTAGES
Risk of electric shock. The pow
er wiring to the system must be properly protected
and the roung must be away from possible hazards.
WARNING: HOT SURFACE
Risk of burn injury
. The exhaust of the dry pumping system will heat up when the
pump is in operaon.
CAUTION: ELECTRICAL SAFETY
Risk of damage t
o equipment. Do not connect voltages greater than specied in this
manual to the control/interface connecons as damage can be caused to the
interface control.
WARNING: HAZARDOUS VOLTAGES
Risk of electric shock. The secondary protecve earth (ground) is required in case of
failure of the primary earth and because pump lters can cause high earth leakage
current. Refer to Table: General electrical data.
Note:
With respect to European Electromagnec Compability (EMC) requirements for
harmonics and icker, the iXM must be treated as Class A (industrial) as dened by
EN61326. The iXM is not intended for use in domesc buildings, or in properes directly
connected to an electrical supply network which also supplies domesc buildings.
All systems are supplied already congured for the electrical supply. Low voltage
(200 V a.c. to 230 V a.c.) and high voltage (380 V a.c. to 460 V a.c.) ranges cannot be
recongured.
Mains supply cable connecon
WARNING: HAZARDOUS VOLTAGES
Risk of electric shock. The mains connect
or is not approved for connecon and
disconnecon under load.
Refer to Electrical supply saf
ety on page 37 before you connect the system to the mains
supply.
Two types of electrical supply connector are used on the system. Refer to Electrical data
on page 18 for details of the connector types the systems to which they are connected.
10/2020 - ©Edwards Limited
Page 38M56635880_D
M56635880_D - Inst
allaon