13
3.6 SETTING THE CORE TEMPERATURE
From the “COOKING PARAMETERS” screen (Fig.11), touching the symbol displays the “ADDITIONAL
FUNCTIONS” screen (Fig.12). Touching the “switch” ( ) activates the “CORE PROBE” function ( );
touch the symbol to confirm. The “CORE PROBE COOKING PARAMETERS” screen (Fig.13) appears.
Touching the value of the symbol it is possible to set the desired value using the keyboard that
appears (Fig.14).
Fig.11 Fig.12 Fig.13 Fig.14
Warning
The pin of the probe must be inserted in the appropriate seat, making sure that the “socket” zone
A of the probe is positioned as in Fig. 15 such that it does not interfere with the metallic structure
of the door when it is closed.
INSIGHTS:
COOKING WITH CORE PROBE
There are two parameters to be set to cook with core probe: core temperature and cooking temperature.
The cooking time is no longer a control parameter and so does not appear on the “summary screen”.
If the cooking cycle consists of a single step, the oven works until the temperature detected by the core
probe is reached inside the food. If the cooking cycle consists of several steps and core probe cooking is
enabled in one of them, once the temperature detected by the core probe is reached, the oven continues
to work switching to the next step.
If, during a cooking cycle with needle shaped thermal probe (core probe) the probe is not properly
connected, the display shows an error with corresponding sound alarm.
IMPORTANT
The needle shaped thermal probe must be inserted inside the food, in the thickest area, avoiding
contact with any bones.
If a cooking cycle with core probe is enabled, the needle shaped thermal probe must already be
connected to the specific socket on the bottom of the oven; otherwise, the display will show the
corresponding alarm.
With the door closed, the needle shaped thermal probe cable must pass between the door gasket
(bottom area) and the door itself.