Troubleshooting with software
36
EXPLANATION
Quits sending master frames. Sending is retrieved with START (page 36).
5.6.10 REC - Reconfigure (D)
This command alters the functionality of the Multifunction Vehicle
Bus. Consider the operative situation carefully before using this
command on board a train.
SYNTAX
REC [s]
s = configure as slave
The optional parameter is only applicable in the Debug Mode. See
MVB_MODE (page 44).
EXPLANATION
In normal mode
Use this command to reconfigure MVB-Asic. If you have modified logical ports through
the debug terminal, you must execute this command in order to validate the
modifications for MVB traffic.
You can use this command whenever you want to reconfigure MVB-Asic for any
reason, even you have not done any modifications.
In debug mode
The optional parameter [s] is only applicable in debug mode. You can configure the
module to act as a slave. In this situation, the configuration you created with the
command CS (page 44) becomes the configuration of the module. E.g. dbg>rec s
With the command dbg>rec the module becomes a master and it polls the slave
configured with the command CS.
5.6.11 START (D)
This command alters the functionality of the Multifunction Vehicle
Bus. Consider the operative situation carefully before using this
command on board a train.