Troubleshooting with software
43
EXPLANATION
Use this command to test the EEPROM memory. The test takes approximately 22
seconds. It is performed in four phases, which are
1) Read EEPROM to Shared Memory.
2) Compare EEPROM content to the configuration in Shared Memory.
3) Program EEPROM from the configuration in Shared Memory.
4) Compare EEPROM content to the configuration in Shared Memory.
Parts 2 and 4 must be OK for the test to pass. After the test you must reset the MVB
module with the command RESET (page 47).
EXAMPLE
dbg>test_eeprom
Testing EEPROM...1...2...3...4...PASSED.
dbg>reset
The numbers printed on display during the test signify the above detailed phases.
5.8 Software development commands
The debugging software includes a set of commands primarily intended for software
development.
The software development commands include
AS
CS
MVB_MODE
LOP
LOS
LPORT
RESET (D)
VER
The following sections describe these commands in alphabetical order.
5.8.1 AS - Active Slave
SYNTAX
AS addr16