NP-DK50-10-16_01-2022-MD - 12 - 01/2022
Tab. 3
8 10 bar
DK50-10 Z
DK50-10 S
DK50-10 Z/M
DK50-10 S/M
Rated voltage /
frequency (*)
V / Hz
230 /
50/60
115 /
60
230 /
50/60
115 /
60
230 /
50/60
115 /
60
230 /
50/60
115 /
60
Performance
at 8 bar
Lit.min-1
60/70
70
60/70
70
50/60
60
50/60
60
Working pressure (**)
bar
8.0 10.0
8.0 10.0
8.0 10.0
8.0 10.0
Rated current
A
4.1/5.1
9.2
4.1/5.1
9.2
4.3/5.3
9.4
4.4/5.4
9.4
Motor power
kW
0.55
0.55
0.55
0.55
Air tank volume
Lit.
10
10
10
10
Air quality filtration
m
-
-
0.1
0.1
Maximum operating
pressure of safety
valve
bar
12.0
12.0
12.0
12.0
Noise level at 5 bar
LpfA
[dB]
≤64/≤66
≤66
≤46/≤49
≤49
≤65/≤67
≤67
≤49/≤52
≤52
Duty cycle
S1-100%
S1-100%
S1-100%
S1-100%
PDP drying
performance at 7 bar
-
-
+3°C
+3°C
Time to fill air tank from
0 to 9 bar
s
85/75
75
85/75
75
96/82
82
96/82
82
Dimensions (net)
w x d x h
mm
485x350x553
580x440x655
544x350x553
649x440x655
Net weight (***)
kg
38
53
44
61
Classification under EN 60601-1
Class I.
Notes:
(*) When ordering, state the version of the compressor
(**) For other range of pressure:consult with the supplier
(***) Information about the weight is for informative purposes only and applies to the product without any
additional accessories.
Dependence of compressor output on working pressure