Page #24 background imageLoading...
Page #24 background image

22
6.4 ALARM
The Alarm feature of your gauge allows you to set an audible and visual alarm when taking measurements.
If the alarm is switched on, the green light on the front panel of the gauge is illuminated. If the measurement
falls below the value set by the user, a red light shows on the front panel of the gauge and the beeper is
sounded (if it is switched on).
Use of the red light and beeper improves the speed and efficiency of the inspection process by eliminating
constant viewing of the reading displayed.
To switch beeper on/off
1. While the gauge is off, press and hold down
ALRM key.
2. Switch on the gauge.
3. Release ALRM key.
The gauge will display bEEP OFF or bEEP On
depending on whether the beeper is on or off.
4. Repeat steps 1 to 3 to toggle between bEEP
ON and bEEP OFF.
1. Switch on the gauge.
2. Press MODE key to activate features and
settings.
3. Press UP or DOWN arrow keys to scroll to
bEEP.
The gauge will display bEEP OFF or bEEP On
depending on whether the beeper is on or off.
4. Press SEND key to toggle the status of the
beeper on/off.
5. Press MODE key when finished.
Elcometer 207
Elcometer 207DL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elcometer 207 and is the answer not in the manual?

Elcometer 207 Specifications

General IconGeneral
BrandElcometer
Model207
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals