30
8.5 DELETING CONTENTS OF ALL BATCHES
1. Press ON/OFF key to switch on the gauge.
2. Immediately press the CLR key. The display will show CLr?
3. Press CLR key once again to clear all batches.
8.6 TRANSFERRING DATA TO A COMPUTER
At the end of the inspection process, or end of the day, the user can transfer the readings in the memory of
the gauge to a computer.
TRANSFERRING ONE BATCH
1. Connect the gauge to a computer and start the data transfer software - see “Transferring readings to a
computer” on page 25.
2. Press ON/OFF key to switch on the gauge.
3. Press MEM key to activate the data logging functions and settings.
4. Press SEND key to enter batch setup.
5. Press UP / DOWN arrow keys to scroll to the batch that is to be sent to the computer.
6. Press SEND key once again to select the batch. The display will flash FILE F-05 (or the batch
selected).
7. Press UP / DOWN arrow keys to scroll to LISt F-05 (or the batch selected) flashing on the display.
8. Press the SEND key to send readings to the computer.
The display will show buSY during data transfer.
Wait until all the data has been transferred.
9. Press the MEM key to exit the data logging functions.