EasyManua.ls Logo

ELECRAFT K3 - Parameter Initialization and Troubleshooting; Parameter Initialization Procedure

ELECRAFT K3
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
Parameter Initialization
Menu parameters are stored in non-volatile memory (EEPROM and/or FLASH). It is possible, though rare, for
parameters to become altered in such a way asto prevent the firmware from running correctly. If you suspect
this, you can reinitialize parameters to defaults, then restore a previously-saved configuration (or re-do all
configuration stepsmanually; notest equipment is required).
If you have a computer available to do configuration save and restore, run the K3 Utility program, then use
the Configuration function to save your present firmware configuration.
If you dont have access to a computer, you should write down your menu parameter settings. The most
important are CONFIG:FLx BW and CONFIG:FLx FRQ (for each installed filter <x>, also tap SU B to
obtain sub receiver crystal filter settings, if applicable). You should also note the settings of option module
enables (all CONFIG menu entries starting with K, e.g. CONFIG:KAT3) . If you dont record your crystal
filter and option settings, you may have to remove the K3s top cover (and sub receiver, if installed) to
verify which options as well as crystalsfilters are installed, as well as the frequency offsetsnoted on the
crystal filters (depends on filter type).
Turn the K3 OFF (using the K3s POWER switch, not your power supply).
While holding inthe SHIFT/LO knob (which is also labeled NORM below), turn power ON bytappingthe
K3s POWER switch. Let go of the SHIFT/LO knob after about 2 seconds. You should now see EE INIT
on the LCD.
When EE INIT completes after a few seconds, you may see ERR PL1 or other error messages due to
reinitialization. Tap DISP to clear each message.
If you have a computer, restore all parameters using the Configuration function ofthe K3 Utility program.
If you dont have a computer, manually re-enter all menu parametersthat you wrote down, above, then re-
do firmware configuration and calibration (starting on pg. 45). You can omit any steps pertaining to
parameters youve already restored manually.
See if the original problem has been resolved.

Table of Contents

Other manuals for ELECRAFT K3

Related product manuals