CTC-1132 868AM 2007.07.18
35
is also scrolled down or up
respectively.
Step 5. After viewing all the fault events, press
“ ” key, a prompt message is
displayed.
C l e a r F a u l t
D s p : ( O K ? )
Step 6. After the fault condition has been
rectified, press “OK” and the fault
event will be cleared and the screen
returns to “Alarm off”.
<
<
N
N
O
O
T
T
E
E
>
>
) In Step 6, if “ “ key is pressed, the
screen returns to “Alarm off”, and the
Yellow LED stays on, the Control
Panel keeps sounding a short beep
every 30 seconds, and the fault event
display retains.
) If the fault condition has not been
rectified, the fault event display will not
be cleared. It will come on again
while you try to arm the system and
the faulty condition inhibits the system
from being armed, the fault message
will be displayed again. The fault
event display can be cleared only after
the fault condition has been rectified.
) Even when the fault messgae is cleared,
the fault event will still retained in the
“Log”.
4. Fault Event Response
z When a fault condition is detected, in
addition to the fault display, the Control
Panel will also respond separately
according to the nature of the fault event.
AC Power Fail
Only the yellow LED will light and
the fault message will be displayed,
no further action will be taken.
Control Panel Low Battery
Any time the Panel battery Low is
detected, yellow LED will light while
this fault message can be viewed
on LCD under “Fault Display”.
Panel Sabotaged
If the Tamper switch on the Control
Panel is triggered while the system
is in Armed and/or Home mode, the
Control Panel will sound an audible
alarm and report “Burglary” alarm.
While if the system is in Disarm
mode, no alarm will be generated.
Sensor Low Battery
If the low battery is detected on any
sensor, yellow LED will light up at
any time while its fault message
can be viewed on LCD under
“Fault Display”.
Sensor Sabotaged
If the Tamper switch on the PIR
Sensor or Door Contact is triggered
while the system is in Arm & Home
mode, the Control Panel will sound
an audible alarm and report
“Burglary” alarm .
While if the system is in Disarm
mode, no alarm will be generated.
Sensor out-of-order
The PIR Sensor, Door Contact,
Water Sensor and Smoke Detector
will send supervised-signal to the
Panel at intervals between 60~100
min. The system will according to
the setting of the supervision send
report.
When the Control Panel cannot
receive the supervised signal from
the device for preset supervisory
period, the Control Panel will
sound an audible alarm and yellow
LED will light while this fault
message can be viewed on LCD
under “Fault Display”.
<
<
N
N
O
O
T
T
E
E
>
>
) The supervision function activates in
Arm/Home/Disarm Mode.
) For Setting Supervision, please refer to
IV. Special Setting 13. Supervision.
While the system is in Disarmed
mode, no alarm event will be
generated.
Interference
When the system is programmed
with Interference Detection On, and
when there is an interference