FAN MOTOR COMMON
30:1 O.H. FAN MOTOR
This error code will be shown if the control system detects that the input OH FAN MOTOR is deactivated during pro-
gram run.
The overheating protection is automatically restored. When the overheating protection is restored the error code is
automatically reset and the ongoing program will continue. A long press on the control knob/start button will make
the control system reset and the ongoing program will be ended.
The error code can be trigged if:
The motor is very warm. Check that the vent holes in the motor are not covered.
If the overheating protection is not trigged, but there is still an error code:
Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.