Service Manual
5.2 Outlet air
5.2.1 Overheating thermostat
Description
The outlet overheating thermostat is placed behind the lint filter next to the fan on the front of the machine.
The outlet overheating thermostat ensures that the machine does not overheat during program operation.
The outlet overheating thermostat opens automatically and has to be reset manually.
Resetting
Disconnect the power to the machine. Gas heated machine: Shut off the manual gas valve.
Remove the filter door.
Remove the lint filter and demount the panel.
Press the reset button (A) on the overheating thermostat.
Note!
Resetting must not be done before the cause for overheating is verified and resolved.
fig.7860
Remount the panel, lint filter and the filter door.
Replacement of overheating thermostat
Disconnect the power to the machine. Gas heated machine: Shut off the manual gas valve.
Remove the filter door.
Remove the lint filter and demount the panel.
Disconnect the overheating thermostat and remove it. Connect the new overheating thermostat.
fig.7861
Remount the panel, lint filter and the filter door.