Service Manual
99
1. Check inputs from indexing sensors FC1 and FC2.
2. Run a positioning sequence with wet load in one compartment to test functionality.
13:7 DRUM NOT ROTATING
The error code is shown if positioning sensor on input on J201 is not indicating rotation when rotation is expected
during program run.
Recommended actions:
1. Check that drive belt is not broken.
2. Check positioning sensor on input J201.
13:8 UNBALANCE SWITCH ON AT PROG START
The error code is shown if unbalance switch is active at program start.
Recommended actions:
1. Check unbalance switch for proper alignment.
2. Check unbalance switch for electrical fault.
13:9 WATER IN DRUM - CALL SERVICE
This error code will be shown if the control system detects water above safety level when program is finished.
Possibly caused by broken inlet valve and / or drain valve.
Recommended actions:
1. Turn off water inlet to machine.
2. Manually open the drain valve.
3. Check reason for valve malfunction.
13:10 WATER IN DRUM - CALL SERVICE
This error code will be shown if the control system detects water above safety level in idle mode. Possibly caused by
broken inlet valve and / or drain valve.
Recommended actions:
1. Turn off water inlet to machine.
2. Manually open the drain valve.
3. Check reason for valve malfunction.
13:11 UNLOADING DOOR NOT LOCKED
This error code will be shown if the control system has not detected the input UNLOADING DOOR LOCKED to be ac-
tive within a certain time after closing the unloading door.
Possible causes:
This can be caused by a mechanical problem preventing door lock to lock, defective door lock, loose cable connec-
tion to door lock, broken cables to door lock or mechanical problem with emergency opening of the door.
Recommended actions:
1. Check door lock functionality in service program, by activating door lock and then by monitoring input status
under Check inputs and outputs.
2. Check electrical connections by reading inputs at the same time as cables carefully moved/pulled.
3. Carefully knock on the door lock unit to locate intermittent errors.
13:12 LOADING DOOR NOT LOCKED
This error code will be shown if the control system detects that the input LOADING DOOR LOCKED has been deacti-
vated during an on-going program.
Possible causes:
This can be caused by a mechanical problem preventing door lock to lock, defective door lock, loose cable connec-
tion to door lock, broken cables to door lock or mechanical problem with emergency opening of the door.
Recommended actions: