Where :
Exxxx ID xx is the description of the apparatus with indication of the ID number
SMS String is a customizable string of 10 characters
+39xxxxxxxxxx is the telephone number of origin of the last command
STBY/ON AIR indicates (command) that the machine is in Standby (Off)/On Air
-3dB Alarm indicates that the machine is working below the-3dB
Status is the response to an SMS status command
Command is the confirmation to a command
No mains xx m indicates that the machine has been off for the indicated time (in minutes)
NoAudio indicates that the machine is in no audio alarm
AudioOK indicates that the audio was restored to the level required
xxx Messaggio di segnalazione indicates a cause of arrest or a major signaling
FWD yyyyy W indicates the forward power
REFL yyyyy W indicates the reflected power
FRQ xxx.xxMHz indicates the frequency
VDS xxx.xV indicates the voltage
IDS xxx.xxA indicates the current
TEMPMAX xxx.xC indicates the max temperature
TEMPENV xxx.xC indicates the environmental temperature
Set are settings information
[TRG]/[24hTRG]xxxxxW indicates the target power
SmsOver-3dB ON/OFF indicates that the SMS to restore power is ON/OFF
PwrAdj xxx% indicates the correction of the display of forward power
Ver x.xx-x.xx indicates the firmware/datamap release
MaxPwr xxxxxW indicates the power omologation