69
4 Maintenance
Maintenance
4.1 Device overview
We report here the images of how, less than specific customizations, the apparatus out
by the manufacturer.
If necessary, refer to these to restore the configuration of the transmitter.
The figures are related to ETG5000. For ETG3500 and ETG2500 the only significant diffe-
rences to mention are that:
• in ETG3500 are absent the RF modules n.1 and n.7, and the connections between
modules and concentrator board are to be carried out so
module n.2 to CN1 on concentrator board
module n.3 to CN2 on concentrator board
module n.4 to CN3 on concentrator board
module n.5 to CN4 on concentrator board
module n.6 to CN5 on concentrator board
• ETG2500 are absent the RF modules n.1, n.4, and n.7, and the connections between
modules and concentrator board are to be carried out so
module n.2 to CN1 on concentrator board
module n.3 to CN2 on concentrator board
module n.5 to CN3 on concentrator board
module n.6 to CN4 on concentrator board
For more details, to carry out repairs, if you are an authorized technician or bodies, you
can request at the Manufacturer the Service Manual, including wiring diagrams.