MES1000, MES2000 Ethernet Switches 169
Privileged EXEC mode commands
Command line request in Privileged EXEC mode appears as follows:
console#
Table 5.195 Privileged EXEC mode commands
Command
Value
Action
show power inline
[gigabitethernet gi_port |
fastethernet fa_port]
gi_port: {1..3/0/1..28};
fa_port: {1..3/0/1..24}
Show the power supply state for all interfaces with PoE
support or for the selected interface only.
show power inline
consumption
[gigabitethernet gi_port |
fastethernet fa_port]
-
Show the power supply characteristics for all PoE-interfaces of
the device or for the selected interface only.
show power inline version
-
Show the PoE subsystem controller firmware version.
Example execution of commands
Show the power supply state for all the device interfaces
console# show power inline
Port based power-limit mode
Unit Power Nominal Consumed Usage Traps Temp (C)
Power Power Threshold
---- ------- ------- ------- ------ -------- --------
1 On 300 Watts 50 Watts (17%) 95 Disable 0
2 Off 1 Watts 0 Watts (0%) 95 Disable 0
3 Off 1 Watts 0 Watts (0%) 95 Disable 0
4 Off 1 Watts 0 Watts (0%) 95 Disable 0
Port Powered Device State Status Priority Class
----- -------------- ----------- -------- -------- -------
gi1/0/1 IP Phone Model A Auto On High Class0
gi1/0/2 Wireless AP Model A Auto On Low Class1
gi1/0/3 Auto Off Low N/A
...
Show the power supply state for the selected interface
console# show power inline gi1/0/1
Port Powered Device State Status Priority Class
----- -------------- ------- ------ -------- -------
gi1/0/1 IP Phone Model A Auto On High Class0
Time range:
Power limit (for port power-limit mode): 30W
Port Status: Port is on - valid capacitor/resistor detected
Overload Counter: 0
Short Counter: 0
Denied Counter: 0
Absent Counter: 0
Invalid Signature Counter: 0
Description of the displayed power supply parameters is listed in the table.
Table 5.196Power supply status parameters.
Power
Status of the PoE power supply subsystem
Nominal Power
Rated power of the PoE subsystem power supply unit