EasyManua.ls Logo

Embraer 190 - Power Plant; Operational Limits; Oil Temperature

Embraer 190
484 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AIRPLANE
FLIGHT
M
ANUAL
LIMITATIONS
ANAC APPROVED 2-40
REVISION 1 code 02 Page 1
AFM
-
1912
POWER PLANT
ENGINES
Two General Electric CF34-10E6A1.
OPERATIONAL LIMITS
PARAMETER MIN MAX
N1 - 100%
N2 59.3% 100%
ITT: - -
Ground Start 740°C
Inflight Start 875°C
Normal and Maximum Takeoff
and Go Around
- 983°C (1) (2)
Maximum Continuous - 960°C
OIL PRESSURE 25 psi (3) -
OIL TEMPERATURE: - -
Continuous - 155°C
NOTE: 1) Time limited to 5 minutes. The ITT limits for Takeoff/Go-
around and Maximum Takeoff/Go-around thrust ratings are
based on ten minutes periods.
2) ITT transients above the nominal ITT limits are allowed to
Normal and Maximum takeoff, up to 5.5°C for 2 seconds,
4.4°C for 5 seconds, 3.6°C for 15 seconds and 2.4°C for 30
seconds.
3) During starts with oil temperature below –22°C the minimum
oil pressure is 5 psi, time limited to 2 minutes.