EMERGENCY
PROCEDURES
AIRPLANE
FLIGHT
4-10 ANAC APPROVED
Page 4 code 01 REVISION 7
ELECTRICAL EMERGENCY
LAND AT THE NEAREST SUITABLE AIRPORT.
Limit the airspeed to 150 KIAS minimum, start the APU, reset (set to
off, then to auto) IDG 1 and IDG 2 and set the emergency lights to off.
CAUTION: ONLY TWO APU START ATTEMPTS ARE ALLOWED.
If ELEC EMERGENCY message extinguishes, reset (push in, then
out) the flight controls mode buttons (spoilers, elevators and rudder).
For landing configuration, arm the emergency lights, push in the
ground proximity flap override button, set slat/flap to 3 and set
V
REF FULL
+ 20 KIAS.
CAUTION:
FOR THE EMBRAER 190, MULTIPLY THE FULL FLAPS
UNFACTORED LANDING DISTANCE BY 1.35.
FOR THE EMBRAER 195, MULTIPLY THE FULL FLAPS
UNFACTORED LANDING DISTANCE BY 2.30.
If ELEC EMERGENCY message persists, exit and avoid icing
conditions and limit the altitude to 10000 ft or MEA (whichever is
higher) maximum. If BATT DISCHARGING message is presented,
deploy the RAT manually and set TRU 1 and TRU 2 to off.
(Continue on the next page)