AIRPLANE
FLIGHT
MANUAL
EMERGENCY
PROCEDURES
CTA APPROVED
4-22
ORIGINAL
code 01 Page 3
AFM-1912
HYDRAULIC SYSTEM 1 OR 2 OVERHEAT
Set the associated electric hydraulic pump to off and push the
associated engine pump shutoff button in.
If HYD 1 (2) SOV FAIL message is presented, LAND AT THE
NEAREST SUITABLE AIRPORT and accomplish the Engine
Shutdown Procedure.
Accomplish the appropriate Loss of Hydraulic System Procedure.
HYDRAULIC SYSTEM 3 OVERHEAT
Set the electric hydraulic system 3 pump A and pump B to OFF.
Relevant Inoperative Items:
Outboard Aileron Actuators.