Appendix B: Product Certifications
July 2015
62
Product Certifications
Special Condition for Safe Use:
1. Explosion Hazard. Do not disconnect equipment when a
flammable or combustible atmosphere is present.
B.5.3 Europe
N1 ATEX Type n
Certificate: Baseefa07ATEX0056X
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings: II 3 G Ex nA IIC T4 Gc,
T4(-40 °C T
a
+65 °C), V
MAX
= 28Vdc
Special Conditions for Safe Use (X):
1. The equipment is not capable of withstanding the 500 V
insulation test required by clause 6.5.1 of EN
60079-15:2010. This must be taken into account when
installing the equipment.
2. The surface resistivity of the antenna is greater than
1GΩ. To avoid electrostatic charge build-up, it must not
be rubbed with a dry cloth or cleaned with solvents.
ND ATEX Dust
Certificate: Baseefa07ATEX0057X
Standards: EN 60079-0: 2012, EN 60079-31: 2009
Markings: II 3 D Ex tc IIIC T135 °C Dc,
(-40 °C T
a
+65 °C)
Special Condition for Safe Use (X):
1. The surface resistivity of the antenna is greater than
1GΩ. To avoid electrostatic charge build-up, it must not
be rubbed with a dry cloth or cleaned with solvents.
B.5.4 International
N7 IECEx Type n
Certificate: IECEx BAS 07.0012X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T4 Gc, T4(-40 °C T
a
+65 °C),
V
MAX
= 28Vdc
Special Conditions for Safe Use (X):
1. The apparatus is not capable of withstanding the 500 V
electrical strength test as defined in Clause 6.5.1 of IEC
60079-15:2012. This must be taken into account during
installation.
2. The surface resistivity of the antenna is greater than
1GΩ. To avoid electrostatic charge build-up, it must not
be rubbed with a dry cloth or cleaned with solvents.
NF IECEx Dust
Certificate: IECEx BAS 07.0013X
Standards: IEC 60079-0: 2011, IEC 60079-31: 2008
Markings: Ex tc IIIC T135 °C Dc, (-40 °C T
a
+65 °C)
Special Condition for Safe Use (X):
1. The surface resistivity of the antenna is greater than
1GΩ. To avoid electrostatic charge build-up, it must not
be rubbed with a dry cloth or cleaned with solvents.
B.5.5 Brazil
N2 INMETRO Type n
Certificate: UL-BR 15.0350X
Standards: ABNT NBR IEC 60079-0:2008 + Errata
1:2011, IEC 60079-15:2012;
Markings: Ex nA IIC T4 Gc, T4(-40 °C T
a
+65 °C)
Special Condition for Safe Use (X):
1. See certificate for special conditions.
B.5.6 China
N3 China Type n
Certificate: CNEx13.1929X
Standards: GB3836.1 – 2010, GB3836.8 - 2003
Markings: Ex nA nL IIC T4 Gc
Special Condition for Safe Use (X):
1. See certificate for special conditions.
B.5.7 Japan
N4 TIIS Type n
Certificate: T64855
Markings: Ex nA nL IIC T4
B.5.8 EAC – Belarus, Kazakhstan, Russia
NM Technical Regulation Customs Union (EAC) Type n
Certificate: RU C-US.ГБ05.B.00578
Markings: 2Ex nA IIC T4 X;
T4(-40 °C T
a
+65 °C)
IP66;
B.5.9 Combinations
KD Combination of N1, N5, and N6