October 2015
Service Instructions
127072E Rev. C
15
Section 3: Actuator Reassembly
Actuator Reassembly
3�2�30 Torque tighten hex cap screws (1-110) until a nal lubricated torque, as listed in
the following table, has been achieved.
Table 2� Housing Cover Screw Quantity and Torque
Model Qty�
TORQUE (±5%)
Model Qty�
TORQUE (±5%)
Lbf-ft� N-m Lbf-ft� N-m
G01 4 40 54 G5 8 100 136
G2 6 40 54 G7 8 100 136
G3 8 40 54 G8 12 100 136
G4 8 40 54 G10 16 100 136
NOTE:
Complete step 3.2.32 on G5, for G10 model actuators. For G01 through G4 model
actuators skip step 3.2.32 and proceed to step 3.2.33.
3�2�31 On G5 through G10 models:
3�2�31�1 Place lockwashers (1-115) onto hex cap screws (1-120).
NOTE:
Hex cap screws (1-120) are only used as "hole" llers and serve to protect threads from
environment.
3�2�32 Install and tighten hex cap screws (1-120) with lockwashers (1-115).
3�2�33 Install thrust bearing (2-110) onto position indicator (1-140).
3�2�34 Install O-ring seal (2-100) onto position indicator (1-140).
3�2�35 Install upper bearing (2-120) into yoke cover (1-150).
3�2�36 Install rod wiper (2-80) into yoke cover (1-150).
3�2�37 Install O-ring seal (2-70) into yoke cover (1-150).
3�2�38 Install yoke cover (1-150) onto housing cover (1-20) and over position indicator
assembly (1-140).
NOTE:
During yoke cover installation be careful not to damage O-ring seal (2-70) and rod wiper (2-80).
3�2�39 Place lockwashers (1-170) onto hex cap screws (1-160).
3�2�40 Install and tighten hex cap screws (1-160) with lockwashers through yoke cover
(1-150) and into housing cover (1-20).
3�2�41 Vent check assembly installation as follows:
3�2�41�1 For G01, G2 and G3 housing (1-10) using pipe sealant install one vent
check assembly (13) into the front of housing (1-10).
3�2�41�2 For G2 and G3 housing (1-10) using pipe sealant install one vent check
assembly (13) into the top area of housing cover (1-20).
3�2�41�3 For G4 through G10 housing (1-10) using pipe sealant install two vent
check assemblies (13) into the front of housing (1-10).

Table of Contents

Other manuals for Emerson Bettis G2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis G2 Series and is the answer not in the manual?

Emerson Bettis G2 Series Specifications

General IconGeneral
BrandEmerson
ModelBettis G2 Series
CategoryController
LanguageEnglish

Related product manuals