Actuator model 500
• Enter setup conguration: move switch SW3 to position ON (conguration function)
• Move switch SW4 to position 9
• Move switch SW6 to position 1
• Conrm by pushing ENTER pushbutton SW5
• When pushing SW5, the red LED switches on for conrmation
• Exit setup conguration (move switch SW3 to position 1) or proceed to the
next parameter
Actuator model 1000
• Enter setup conguration: move switch SW3 to position ON (conguration function)
• Move switch SW4 to position 9
• Move switch SW6 to position 3
• Conrm by pushing ENTER pushbutton SW5
• When pushing SW5, the red LED switches on for conrmation
• Exit setup conguration (move switch SW3 to position 1) or proceed to the
next parameter
Actuator model 2000
• Enter setup conguration: move switch SW3 to position ON (conguration function)
• Move switch SW4 to position 9
• Move switch SW6 to position 4
• Conrm by pushing ENTER pushbutton SW5
• When pushing SW5, the red LED switches on for conrmation
• Exit setup conguration (move switch SW3 to position 1) or proceed to the