5.4 Input Power Requirements
The input power requirements for the LPX Power Supply are:
100 - 120 VAC, 50/60 Hz (North American and Japanese models)
200 - 240 VAC, 50/60 Hz (Export models only, including Japan, optional for North America)
The LPX Power Supply is equipped with an IEC-type power cord connector. The unit
requires a single-phase, three-wire, 50/60 Hz power source. Check data tag for voltage
requirements for your unit.
The system is fuse-protected with a replaceable glass fuse, 5x20mm, slow-blow type
(refer to the data tag on the system) located on the rear of the unit, as part of the IEC
power connector. Under normal operating conditions, this fuse should not fail. If it is
necessary to replace the fuse, remove the power cord connector, and snap open the fuse
holder located at the base of the connector. If the fuse blows again, contact your local
Branson Service Center or Branson Product Support.
WARNING High Voltage Hazard
To prevent the possibility of electrical shock, always plug the LPX
Power Supply unit into a grounded power source.