100-412-196 REV. 06 53
6.5 Operational Sequence
6.5.1 Energy Mode
In this mode, ultrasonics are determined by the calculated amount of Joules (1 Joule = 1
watt x 1 second) expended during a cycle. Ultrasonics will remain on until the required
amount of energy is reached or until the timeout period has been reached unless a STOP
condition occurs.
The following table shows the parameters of Energy mode, along the default, max. and
min. values.
Entering an illegal value will generate 3 beeps. The system will not accept out-of-range
parameters. (See 7.4 Alarms/Errors for further details).
Table 6.4 Energy Mode Parameters
Parameter Default Max. Value Min. Value
Energy 1 J 9999 J 1 J
Amplitude 50% 100% 10%
Off Time 0.05 s 9.99 s 0.05 s
Ground Detect 0.05 s 0.99 s 0.00 s
NOTICE
You can return to the ready screen without saving any change by pressing the ESC key
at any time.
Table 6.5 Energy Mode Operational Sequence
Step Action Reference
1
Turn on power, wait for the LCD to show ready and current
mode.