50 100-412-196 REV. 06
6.4 System Configuration Registers
To access and modify the system configuration registers:
The table below shows the register number along the description and parameters.
Table 6.2 Modify Registers
Step Action
1 Press the Configuration Key two times while on rdy screen.
2
Use the Up and Down keys to select the register to modify, then press the
Enter key to confirm the selection.
3
Use the Up and Down keys to set the desired parameter, then press enter
to confirm the entered value.
4 Press the ESC key to return to the rdy screen.
Table 6.3 Register Settings
Register Description Parameters
1
Software Version
Shows the current software version installed on the
unit.
N/A
2
Panel Trigger
In OFF position, the user must control the Start/
Stop function through the 9-pin D-Shell connector
on the back of the power supply enclosure. This
mode disables the Start/Stop key from starting a
cycle, but will always permit it stopping a cycle. Test
key is not disabled.
In ON position, the Start/Stop function is controlled
at the front panel of the unit only. The Start/Stop
function is disabled at the 9-pin D-shell connector at
the back of the LPX power supply enclosure.
0 (OFF) Default
1 (ON)
3
Pulse Start
In ON position the user must press the Start/Stop
key for a minimum duration of 10 ms to initiate a
cycle. After 10 ms the Start/Stop key can be
released allowing the system to continue through
the intended cycle. Releasing and pressing the
Start/Stop key again will abort the current process
cycle.
In OFF position the user must continue to hold the
Start/Stop key throughout the duration of the
process cycle. If the Start/Stop key is released
during a cycle then the cycle is aborted.
NOTICE
In both modes the Start/Stop key must be released
before the next cycle can be started.
0 (OFF) Default
1 (ON)