6.6 Save/Recall Weld Preset
Once you have configured a set of parameters for a given weld mode, you can save that
setup/configuration as a Preset. Up to 10 Presets may be saved, using the Save and Recall
functions described in the following table. Presets are saved and recalled using a number,
01 to 10. Presets save all parameters for the setup. Presets are saved until they are over-
written or cleared, and are maintained in memory even if the system is turned off or
unplugged.
Table 6.10 Saving a Weld Preset in Memory
Step Action Reference
1
Set the desired mode and parameters. For more information
see 6.5 Operational Sequence.
Press the Save Preset key while on the ready screen.
2
Preset and Save icon and digits will appear on the LCD.
The digits under the Preset icon shows the preset number.
Select the preset number using the Up/Down Arrow keys,
then press the Enter key.
3
This will save the current settings to the number selected
and will return to the ready screen with the selected preset
value displayed.