74 100-412-196 REV. 06
Ultrasonic power is absent
or inconsistent, or power
supply overloads.
Foreign material is between
horn surface and replaceable
tip. If horn is hot to the touch,
problem may exist with
corroded tip-to-horn interface
Remove, examine, and
clean tip; reinstall tip
Replace tip if corrosion is
excessive
Tip is loose or worn out
Horn is loose or has failed
Tighten or replace
defective tip or horn
Horn stud is loose or has failed Loose or broken studs
must be replaced
Replace defective horn
Converter cable connection is
loose or has failed
Tighten connector to
Converter
Return unit for repair if
cable has failed
Converter has failed Replace defective
Converter, return for
repair
Power supply or controls have
failed
Return for repair
Slight electric shock when
touching a metal part of
the system or lab
equipment contacting the
system.
System is not properly
grounded
Correct electrical ground
to system
Cordset has failed or had
Ground lead removed
Replace cordset
User I/O signals are not
working correctly.
User I/O is not configured
correctly
customer-provided User I/O
components have failed or are
no longer functioning
Verify and correct
connections - See
5.5.2
User I/O Connection
Outputs of User I/O failed Return unit for repair
User I/O signals are
working correctly, but still
overloads.
Call Product Support
Table 7.2 System Trouble Analysis Chart
Symptom Probable Cause Corrective Action