Custom units rate conversion factor (rAtCF)Figure 5-14:
Custom units total conversion factor (totCF)
Use the total conversion factor only when the Units for total have been set to custom
(CUST). This menu will not appear if standard display units are selected for total.
Use Total conversion factor to convert to a custom unit of total display. For example, to
display total as quantity of 2.5 gallon containers when the flow rate units are set to gallons,
enter a conversion factor of 2.500.
Press the Enter button at any time, to accept a setting or press the Menu button to exit
without saving changes.
Custom units total conversion factor (totCF)Figure 5-15:
Custom units grand total conversion factor (GrtCF)
Use the grand total conversion factor only when the Units for grand total have been set to
custom (CUST). This menu will not appear if standard display units are selected for grand
total.
Use the Grand total conversion factor to convert to a custom unit of total display. For
example, to display grand total as a quantity of 2.5 gallon containers when the flow rate
units are set to gallons, enter a conversion factor of 2.500.