A programmed scaled input works with Automatic unit conversions. The units for the
display values being entered are a combination of the programmed Rate unit and the time
unit (timE UNIT) entered in the Scale menu.
For example, if the Rate unit is gallons, and the time unit (timE UNIT) is seconds, the units
for the display values entered in the Scale menu are gallons/second.
Scaling the meter (SCALE)Figure 6-8:
For instructions on how to program numeric values see Section 5.3.
Multi-Point linearization (noPtS)
Up to 32 linearization points can be selected under the noPtS function. The multipoint
linearization can be used to linearize the display for non-linear inputs.
Number of points (noPtS)
Enter number of linearization points. The default value is 2 points. For linear inputs
requiring only 2 scale points, leave the number of points at 2.
Product advanced features
User manual 67