Daniel models 3415, 3416 and 3417 meter specifications (continued)Table 1-1:
Daniel 3415, 3416 and 3417 meter specifications
Velocity range • 100 ft/s (30m/s) with over-range)
• 125 fps (38 m/s) on some line sizes
• Meter meets or exceeds AGA9 (2007) performance
specifications
Performance specificationsTable 1-2:
Models 3415 and 3416
AGA 9 / ISO 17089 Flow rate values (Metric units)
Meter size (DN) 200 to 600
Q
min
(m/s) 0.5
Q
t
(m/s) 3.048
Q
max
(m/s) 30.48
Models 3415 and 3416
AGA 9 / ISO 17089 Flow rate values (US Customary
Units)
Meter size (in) 8 to 24
Q
min
(ft/s) 1.7
Q
t
(ft/s) 10
Q
max
(ft/s) 100
Model 3417
AGA 9 / ISO 17089 Flow rate values (Metric units)
Meter
size
(DN)
200 to
600 750 900 1050
Q
min
(m/
s)
0.5 0.5 05 0.5
Q
t
(m/s) 3.048 2.591 2.29 CF *
Q
max
(m/
s)
30.48 25.91 22.86 CF *
Introduction
14 Gas Ultrasonic Flow Meter