Technical data Cerabar PMC11, PMC21, PMP11, PMP21, PMP23
36 Endress+Hauser
12.2.6 Dead time, time constant
Presentation of the dead time and the time constant:
I
63 %
100 %
t
t
1
t
2
90 %
t
3
A0019786
12.2.7 Dynamic behavior
Analog electronics
Dead time (t
1
) [ms] Time constant (T63), t
2
[ms] Time constant (T90), t
3
[ms]
6 ms 10 ms 15 ms