iTEMP TMT71/72 Operation options
Submenus
Menu Typical tasks Content/meaning
"Diagnostics" Fault elimination:
Diagnosing and eliminating process errors.
Error diagnostics in difficult cases.
Interpretation of device error messages and
correcting associated errors.
"Application" Commissioning:
Configuration of the measurement.
Configuration of data processing (scaling,
linearization, etc.).
Configuration of the analog measured value output.
Tasks during operation:
Reading measured values.
"System" Tasks that require detailed knowledge of the system
administration of the device:
Optimum adaptation of the measurement for
system integration.
Detailed configuration of the communication
interface.
User and access administration, password control
Information concerning the device identification,
HART information and display configuration
Contains all parameters for detecting and analyzing errors:
Diagnostic list
Contains up to 3 error messages currently pending
Event logbook
Contains the last 10 error messages (no longer pending)
"Simulation" submenu
Used to simulate measured values, output values or diagnostic
messages
"Diagnostic settings" submenu
Contains all the parameters for configuring error events
"Min/max values" submenu
Contains the minimum/maximum indicator and the reset option
Contains all parameters for commissioning:
"Measured values" submenu
Contains all the current measured values
"Sensor" submenu
Contains all the parameters for configuring the measurement
"Output" submenu
Contains all the parameters for configuring the analog current output
"HART configuration" submenu
Contains the settings and the most important parameters for HART
communication
Contains all the higher-level device parameters that are assigned for
system, device and user management, including Bluetooth
configuration.
"Device management" submenu
Contains parameters for general device management
"Bluetooth configuration" submenu (option)
Contains the function for enabling/disabling the Bluetooth interface
"Device and user management" submenus
Parameters for access authorization, password assignment, etc.
"Information" submenu
Contains all the parameters for the unique identification of the device
"Display" submenu
Configuration of the display
6.3 Access to the operating menu via the operating tool
6.3.1 DeviceCare
Function scope
DeviceCare is a free configuration tool for Endress+Hauser devices. It supports devices with
the following protocols, provided a suitable device driver (DTM) is installed: HART,
PROFIBUS, FOUNDATION Fieldbus, Ethernet/IP, Modbus, CDI, ISS, IPC and PCP. The tool is
aimed at customers without a digital network in plants and workshops and Endress
+Hauser service technicians. The devices can be connected directly via a modem (point-to-
point) or a bus system. DeviceCare is fast, easy and intuitive to use. It can run on a PC,
laptop or tablet with a Windows operating system.
Source for device description files
See information 28
Endress+Hauser V. 1, Rev. 2, 4-10-2018 23