Operating menu and parameter description iTEMP TMT71/72
Navigation Diagnostics Diagnostic settings Diagnostic behavior
Description Each diagnostic event is assigned a certain diagnostic behavior. The user can change this
assignment for certain diagnostic events. 39
Selection Alarm
Warning
Disabled
Factory setting See the list of diagnostic events 39
Status signal
Navigation Diagnostics Diagnostic settings Status signal
Description Each diagnostic event is assigned a certain status signal at the factory
1)
. The user can
change this assignment for certain diagnostic events. 39
1) Digital information available via HART® communication
Selection Failure (F)
Function check (C)
Out of specification (S)
Maintenance required (M)
No effect (N)
Factory setting See the list of diagnostic events 39
14.1.6 "Min/max values" submenu
Sensor min value
Navigation Diagnostics Min/max values Sensor min value
Description Displays the minimum temperature measured in the past at the sensor input (minimum
indicator).
Sensor max. value
Navigation Diagnostics Min/max values Sensor max value
Description Displays the maximum temperature measured in the past at the sensor input (maximum
indicator).