EasyManua.ls Logo

Endress+Hauser iTEMP TMT71 - 7 System Integration; Overview of Device Description Files; Measured Variables Via HART Protocol; Supported HART Commands

Endress+Hauser iTEMP TMT71
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DRAFT
DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT
DRAFT DRAFT DRAFT
System integration iTEMP TMT71/72
7 System integration
7.1 Overview of device description files
Version data for the device
Firmware version 01.01.zz On the title page of the Operating instructions
On the nameplate 1, 9
Parameter firmware version
Diagnostics Device info Firmware Version
Manufacturer ID 0x11 Manufacturer ID parameter
Diagnostics Device info Manufacturer ID
Device type ID 0x11D0 Device type parameter
Diagnostics Device info Device type
HART protocol revision 7 ---
Device revision 1 On the transmitter nameplate 1, 9
Device revision parameter
Diagnostics Device info Device revision
The suitable device driver software (DD/DTM) for the individual operating tools can be
acquired from a variety of sources:
www.endress.com --> Downloads --> Search field: Software --> Software type: Device
driver
www.endress.com --> Products: individual product page, e.g. TMTx2 --> Documents /
Manuals / Software: Electronic Data Description (EDD) or Device Type Manager (DTM).
Via DVD (please contact your local Endress+Hauser Sales Center)
Endress+Hauser supports all common operating tools from a variety of manufacturers (e.g.
Emerson Process Management, ABB, Siemens, Yokogawa, Honeywell and many others).
Endress+Hauser's FieldCare and DeviceCare operating tools are available for download
(www. endress.com --> Downloads --> Search field: Software --> Application software) or
on the optical data storage medium (DVD) which you can obtain from your local Endress
+Hauser Sales Center.
7.2 Measured variables via HART protocol
The following measured values are assigned to the device variables at the factory:
Device variable Measured value
Primary device variable (PV) Sensor
Secondary device variable (SV) Device temperature
Tertiary device variable (TV) Sensor
Quaternary device variable (QV) Sensor
7.3
Supported HART
®
commands
The HART
®
protocol enables the transfer of measuring data and device data between
the HART
®
master and the field device for configuration and diagnostics purposes.
HART
®
masters such as the handheld terminal or PC-based operating programs (e.g.
FieldCare) need device description files (DD, DTM) which are used to access all the
information in a HART
®
device. This information is transmitted exclusively via
"commands".