Installation iTEMP TMT71/72
Mounting the display on the head transmitter
A0009852
5 Mounting the display
1. Loosen the screw on the terminal head cover. Flip back the terminal head cover.
2. Remove the cover of the display connection area.
3. Fit the display module onto the mounted and wired head transmitter. The fastening
pins must click securely into place on the head transmitter. After mounting, securely
tighten the terminal head cover.
The display can be used only with the appropriate terminal heads - cover with viewing
window (e.g. TA30 from Endress+Hauser).
4.3 Post-installation check
After installing the device, always run the following final checks:
Device condition and specifications Notes
Is the device undamaged (visual inspection)? -
Do the ambient conditions match the device specification (e.g. ambient temperature,
measuring range, etc.)?
See 'Technical data'
section