Operation Liquistation CSF33
98 Endress+Hauser
Menu/Setup/Inputs
Function Options Info
Interval Selection
Daily
Weekly
Monthly
Factory setting
Daily
Daily
If a daily interval is selected, set the Time .
Weekly
If a weekly interval is selected, set the Day
of week and the Time .
Monthly
If a monthly interval is selected, set the Day
of month and theTime .
Time 00:00:00 ... 23:59:59
HH:MM:SS
Factory setting
12:00:00 HH:MM:SS
Input mode External event
Signal slope Selection
Low-High
High-Low
Factory setting
Low-High
Preselect the level change of the signal. ‐‐> If
LowHigh is selected, the high level brings
about the corresponding setting.
Having selected Input mode Armature end position detection (only for version with sampling assembly)
Position Selection
Off
Front (sampling)
Back (dosing)
Factory setting
Off
Setting specifying the assembly position
(front or back) to which the end position
sensor is connected.
Binary input assignment view Overview of the outputs to which this binary
input is linked.
10.4.2 Current inputs
The current input must be assigned an analog signal for the functions described. Active
and passive current inputs are available to connect two-wire or four-wire devices.
For the correct wiring of the current inputs see the "Electrical connection" section →  21
Menu/Setup/Inputs
Function Options Info
Current input S:x
Mode Selection
Off
0..20 mA
4..20 mA
Factory setting
Off
Enter the output signal of the connected
device: 0 to 20 mA or 4 to 20 mA.