EasyManua.ls Logo

Endress+Hauser Micropilot FMR56 - Page 35

Endress+Hauser Micropilot FMR56
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR56, FMR57
Endress+Hauser 35
Avoiding interference echoes
β
α
A0016889
Metal orifice plates, installed at an angle to scatter the radar signals, help prevent interference
echoes
Measurement in a plastic vessel
If the outer wall of the vessel is made of a non-conductive material (e.g. GFRP) microwaves can also
be reflected off interfering installations outside of the vessel (e.g. metallic pipes (1), ladders (2),
grates (3) etc.). Therefore there should be no such interfering installations in the signal beam.