EasyManua.ls Logo

Endress+Hauser Micropilot FMR56 - Temperature Range; Temperature Limit

Endress+Hauser Micropilot FMR56
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR56, FMR57
Endress+Hauser 45
Environment
Temperature range
Measuring device –40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
request
Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.
Remote display FHX50 –40 to 80 °C (–40 to 176 °F)
Remote display FHX50
(option)
–50 to 80 °C (–58 to 176 °F)
1)
1) This range applies if the option JN "Transmitter ambient temperature –50 °C (–58 °F)" has been selected in
order code 580 "Test, certificate. If the temperature is permanently below –40 °C (–40 °F), the chance of
failure increases.
For outdoor operation in strong sunlight:
Mount the device in the shade.
Avoid direct sunlight, particularly in warm climatic regions.
Use a weather protection cover (see accessories).
Temperature limit
The following diagrams only consider functional aspects. Additional restrictions may apply for
certified device versions.
In the event of temperature (T
p
) at the process connection, the permitted ambient temperature (T
a
)
is reduced as indicated in the following diagram (temperature derating) in the table header.
Information on the following derating tables
Feature version Meaning
A 2-wire; 4-20 mA HART
B 2-wire; 4-20 mA HART, switch output
C 2-wire; 4-20 mA HART, 4-20 mA
E 2-wire; FF, switch output
G 2-wire; PA, switch output
K 4-wire 90-253VAC; 4-20 mA HART
L 4-wire 10, 4-48VDC; 4-20 mA HART
FMR56
GT19 housing (plastic PBT)
Temperature specifications: °C (°F)
T
p
P1
T
a
P2
P3
P4
P5
A0019351
Power supply; output (item 2
in the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -40
(-40)
80
(176)
80
(176)
80
(176)
80
(176)
80
(176)
80
(176)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output not used
-40
(-40)
76
(169)
76
(169)
76
(1698)
80
(176)
75
(167)
80
(176)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output used
-40
(-40)
60
(140)
60
(140)
60
(140)
80
(176)
58
(136)
80
(176)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 not used
-40
(-40)
80
(176)
80
(176)
80
(176)
80
(176)
80
(176)
80
(176)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 used
-40
(-40)
74
(165)
74
(165)
74
(165)
80
(176)
73
(163)
80
(176)
-40
(-40)
-40
(-40)
-40
(-40)
- -

Other manuals for Endress+Hauser Micropilot FMR56

Related product manuals