Micropilot FMR60B PROFINET with Ethernet-APL Mounting
Endress+Hauser 11
10.3 Mounting the measuring device
10.3.1 Encapsulated antenna, PVDF 40 mm (1.5 in)
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 50 mm
• Maximum permissible torque: 30 Nm (22 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.
Maximum nozzle length H
max
as a function of the nozzle diameter D
D H
max
50 to 80 mm (2 to 3.2 in) 600 mm (24 in)
80 to 100 mm (3.2 to 4 in) 1 000 mm (24 in)
100 to 150 mm (4 to 6 in) 1 250 mm (50 in)
≥ 150 mm (6 in) 1 850 mm (74 in)
In the case of longer nozzles, reduced measuring performance must be expected.
Please note the following:
• The end of the nozzle must be smooth and free from burrs.
• The edge of the nozzle should be rounded.
• Mapping must be performed.
• Please contact the manufacturer's support department for applications with nozzles
that are higher than indicated in the table.
10.3.2 Drip-off antenna PTFE 50 mm (2 in)
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 55 mm
• Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.