EasyManua.ls Logo

Endress+Hauser Micropilot FMR60B - Mounting the Measuring Device

Endress+Hauser Micropilot FMR60B
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR60B PROFINET with Ethernet-APL Mounting
Endress+Hauser 11
10.3 Mounting the measuring device
10.3.1 Encapsulated antenna, PVDF 40 mm (1.5 in)
Information concerning threaded connections
When screwing in, turn by the hex bolt only.
Tool: open-ended wrench 50 mm
Maximum permissible torque: 30 Nm (22 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.
Maximum nozzle length H
max
as a function of the nozzle diameter D
D H
max
øD
H
max
50 to 80 mm (2 to 3.2 in) 600 mm (24 in)
80 to 100 mm (3.2 to 4 in) 1 000 mm (24 in)
100 to 150 mm (4 to 6 in) 1 250 mm (50 in)
≥ 150 mm (6 in) 1 850 mm (74 in)
In the case of longer nozzles, reduced measuring performance must be expected.
Please note the following:
The end of the nozzle must be smooth and free from burrs.
The edge of the nozzle should be rounded.
Mapping must be performed.
Please contact the manufacturer's support department for applications with nozzles
that are higher than indicated in the table.
10.3.2 Drip-off antenna PTFE 50 mm (2 in)
Information concerning threaded connections
When screwing in, turn by the hex bolt only.
Tool: open-ended wrench 55 mm
Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.

Other manuals for Endress+Hauser Micropilot FMR60B