EasyManua.ls Logo

Endress+Hauser Micropilot FMR60B - Product description; Product design

Endress+Hauser Micropilot FMR60B
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting Micropilot FMR60B PROFINET with Ethernet-APL
12 Endress+Hauser
Maximum nozzle length H
max
as a function of the nozzle diameter D
D H
max
H
øD
max
50 to 80 mm (2 to 3.2 in) 750 mm (30 in)
80 to 100 mm (3.2 to 4 in) 1 150 mm (46 in)
100 to 150 mm (4 to 6 in) 1 450 mm (58 in)
≥150 mm (6 in) 2 200 mm (88 in)
In the case of longer nozzles, reduced measuring performance must be expected.
Please note the following:
The end of the nozzle must be smooth and free from burrs.
The edge of the nozzle should be rounded.
Mapping must be performed.
Please contact the manufacturer's support department for applications with nozzles
that are higher than indicated in the table.
10.3.3 Integrated antenna, PEEK 20 mm (0.75 in)
Information concerning threaded connections
When screwing in, turn by the hex bolt only.
Tool: open-ended wrench 36 mm
Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.
Maximum nozzle length H
max
as a function of the nozzle diameter D
D H
max
H
øD
max
40 to 50 mm (1.6 to 2 in) 200 mm (8 in)
50 to 80 mm (2 to 3.2 in) 300 mm (12 in)
80 to 100 mm (3.2 to 4 in) 450 mm (18 in)

Other manuals for Endress+Hauser Micropilot FMR60B

Related product manuals