Use
In applications with strong dust emissions, the integrated purge air connection can prevent the
antenna from becoming clogged. Pulse operation is recommended.
Purge air pressure range
Pulse operation :
Max. 6 bar (87 psi)
Continuous operation:
200
to 500 mbar (3 to 7.25 psi)
Always use dry purge air.
In general, purging should only be performed to the extent necessary as excess purging can
cause mechanical damage (abrasion).
Container with heat
insulation
1
2
A0032207
If process temperatures are high, the device should be included in the usual container insulation
system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The
insulation should not be higher than the neck of the device (1).