Micropilot FMR67
Endress+Hauser V. 1, Rev. 3, 11-04-2017 39
FMR67, PTFE DN80, UNI flange 316L
Feature 100 "Process
connection"
Feature 90
"Seal"
Process temperature
range
Process pressure range
X3J:
UNI flange DN200/8"/200A,
316L
X5J:
UNI flange DN250/10"/250A,
316L
A5, FKM Viton
GLT
–40 to +150 °C
(–40 to +302 °F)
p
rel
=
–1 to 1 bar (–14.5 to 14.5 psi)
p
abs
< 2 bar (29 psi)
1)
A6, FKM Viton
GLT
–40 to +200 °C
(–40 to +392 °F)
1) The pressure range may be further restricted in the event of a CRN approval
FMR67, flush mount antenna, PTFE DN80, UNI flange, ALU, adjustable
p
-40
(-40)
+150
(+302)
+200
(+392)
0
(+32)
T
p
[°C]
([°F])
1
2
[bar] ([psi])
1 (14.5)
-1 (-14.5)
0 (0)
A0032199
16 FMR67: Permitted range for process temperature and process pressure, antenna, PTFE DN80, UNI flange,
ALU, adjustable
1 Feature 90, seal: A5, FKM Viton GLT
2 Feature 90, seal: A6, FKM Viton GLT
FMR67, PTFE DN80, UNI flange, ALU, adjustable
Feature 100 "Process connection" Feature 90
"Seal"
Process temperature
range
Process pressure
range
XCA:
Alignment unit, UNI 4"/DN100/100A,
aluminum
XDA:
Alignment unit, UNI 6"/DN150/150A,
aluminum
XEA:
Alignment unit, UNI 8"/DN200/200A,
aluminum
XFA:
Alignment unit, UNI 10"/DN250/250A,
aluminum
A5, FKM
Viton GLT
–40 to +150 °C
(–40 to +302 °F)
p
rel
=
–1 to 1 bar
(–14.5 to 14.5 psi)
1)
A6, FKM
Viton GLT
–40 to +200 °C
(–40 to +392 °F)
1) The pressure range may be further restricted in the event of a CRN approval
Dielectric constant
For bulk solids
ε
r
≥ 1.6
Please contact Endress+Hauser for applications with lower dielectric constants than indicated.
For dielectric constants (DC values) of many media commonly used in various industries refer
to:
the Endress+Hauser DC manual (CP01076F)
the Endress+Hauser "DC Values App" (available for Android and iOS)