Endress+Hauser V. 1, Rev. 3, 11-04-2017 43
FMR67 DN80 antenna, purge air connection
R
R
ø80 (3.15)
A
B
H
233 (9.17)
162 (6.38)
ø70 (2.76)
øD
25.5 (1.00)
ø60 (2.36)
A0032172
22 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F
R Bottom edge of housing
Feature 100 "Process
connection"
Suitable for Material Pressure
rating
øD H
AGJ:
NPS 3" Cl.150 RF,
316/316L
ASME B16.5
NPS 3" Cl.150 RF
316/316L CL.150
190.5 mm
(7.5 in)
23.9 mm
(0.94 in)
AHJ:
NPS 4" Cl.150 RF,
316/316L
ASME B16.5
NPS 4" Cl.150 RF
316/316L CL.150
228.6 mm
(9 in)
23.9 mm
(0.94 in)
CGJ:
DN80 PN10/16 B1, 316L
EN1092-1
DN80 PN10/16 B1
316L PN10/16
200 mm
(7.87 in)
20 mm
(0.79 in)
CHJ:
DN100 PN10/16 B1, 316L
EN1092-1
DN100 PN10/16 B1
316L PN10/16
220 mm
(8.66 in)
20 mm
(0.79 in)
KGJ:
10K 80A RF, 316L
JIS B2220
10K 80A RF
316L 10K
185 mm
(7.28 in)
18 mm
(0.71 in)
KHJ:
10K 100A RF, 316L
JIS B2220
10K 100A RF
316L 10K
210 mm
(8.27 in)
18 mm
(0.71 in)

Table of Contents