Proline Promag 50H, 53H
Endress+Hauser 33
Clamp DIN 32676 Sensor Fits to di G L H × B
1.4404 / 316L
5*H**-0***********
DN
[mm]
Piping
DIN 11850 [mm] [mm] [mm] [mm]
A0005556
2 to 8 Tube 14 × 2
(DN 10)
10 34.0 41.0 62 × 42
15 Tube 20 × 2
(DN 15)
16 34.0 41.0 62 × 42
25 (DIN) Tube 30 × 2
(DN 25)
26 50.5 44.5 72 × 55
Fitting length = (2 × L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Tri-Clamp for L14 AM7 Sensor Fits to di G L H × B
1.4404 / 316L
5*H**-1***********
DN
[mm]
Piping
OD [mm] [mm] [mm] [mm]
A0003872
2 to 8 Tube 12.7 × 1.65
(OD ½")
9.4 25.0 28.5 62 × 42
15 Tube 19.1 × 1.65
(ODT ¾")
15.8 25.0 28.5 62 × 42
25 (1" ANSI) Tube 25.5 × 1.65
(ODT 1")
22.1 50.4 28.5 72 × 55
Fitting length = (2 × L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling SC DIN 11851 Sensor Fits to di G L H × B
Threaded adapter; 1.4404 / 316L
5*H**-2***********
DN
[mm]
Piping
DIN 11850 [mm] [mm] [mm] [mm]
A0005553
2 to 8 Tube 12 × 1
(DN 10)
10 Rd 28 × 1/8" 44 62 × 42
15 Tube 18 × 1.5
(DN 15)
16 Rd 34 × 1/8" 44 62 × 42
25 (DIN) Tube 28 × 1
or 28 × 1.5
(DN 25)
26 Rd 52 × 1/6" 52 72 × 55
Fitting length = (2 × L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling DIN 11864-1 Sensor Fits to di G L H × B
Aseptic threaded adapter, Form A
1.4404 / 316L
5*H**-3***********
DN
[mm]
Piping
DIN 11850 [mm] [mm] [mm] [mm]
A0005558
2 to 8 Tube 13 × 1.5
(DN 10)
10 Rd 28 × 1/8" 42 62 × 42
15 Tube 19 × 1.5
(DN 15)
16 Rd 34 × 1/8" 42 62 × 42
25 (DIN) Tube 29 × 1.5
(DN 25)
26 Rd 52 × 1/6" 49 72 × 55
Fitting length = (2 × L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
G
di
L
HxB
G
di
L
HxB
G
di
HxB
L
G
di
L
HxB