Proline Promag 50H, 53H
40 Endress+Hauser
Process connections with aseptic gasket seal DN 40 to 100 (1½ to 4")
Weld socket for DIN Sensor Fits to di G D L L1 LK
1.4404 / 316L
5*H**-U***********
DN
[mm]
Piping
DIN 11850 [mm] [mm] [mm] [mm] [mm] [mm]
A0005541
40 42 × 2 38.0 43 92 42 19 71.0
50 54 × 2 50.0 55 105 42 19 83.5
65 70 × 2 66.0 72 121 42 21 100.0
80 85 × 2 81.0 87 147 42 24 121.0
100 104 × 2 100.0 106 168 42 24 141.5
– Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Weld socket for ODT/SMS Sensor Fits to di G D L L1 LK
1.4404 / 316L
5*H**-V***********
DN
[mm]
Piping
OD/SMS [mm] [mm] [mm] [mm] [mm] [mm]
A0005541
40 38.1 × 1.65 35.3 40 92 42 19 71.0
50 50.8 × 1.65 48.1 55 105 42 19 83.5
65 63.5 × 1.65 59.9 66 121 42 21 100.0
80 76.2 × 1.65 72.6 79 147 42 24 121.0
100 101.6 × 1.65 97.5 104 168 42 24 141.5
– Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Clamp ISO 2852, Fig. 2 Sensor Fits to
piping
Clamp
ISO 2852
di G D L LK
1.4404 / 316L
5*H**-W***********
DN
[mm]
ISO 2037 /
BS 4825-1
Diameter
[mm] [mm] [mm] [mm] [mm] [mm]
A0005544
40 38.0 × 1.6 38.0 35.6 50.5 92 68.5 71.0
50 51.0 × 1.6 51.0 48.6 64.0 105 68.5 83.5
65 63.5 × 1.6 63.5 60.3 77.5 121 68.5 100.0
80 76.1 × 1.6 76.1 72.9 91.0 147 68.5 121.0
100 101.6 × 2.0 101.6 97.6 119.0 168 68.5 141.5
– Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!