Operation Proline Prosonic Flow B 200 HART
102 Endress+Hauser
Function scope of the "Reset all totalizers" parameter
Options Description
Reset + totalize Resets all totalizers to 0 and restarts the totaling process. This deletes all the flow
values previously totalized.
Navigation
"Operation" menu → Operation
‣
Totalizer handling
Control Totalizer 1 to 3
Preset value 1 to 3
Reset all totalizers
Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Control Totalizer One of the following options is
selected in the Assign process
variable parameter (→ 85)
of the Totalizer 1 to 3
submenu:
• Volume flow
• Corrected volume flow
• Corrected methane volume
flow
*
• Mass flow
• Energy flow
*
Control totalizer value. • Totalize
• Reset + hold
• Preset + hold
• Reset + totalize
• Preset + totalize
• Hold
Totalize
Preset value One of the following options is
selected in the Assign process
variable parameter (→ 85)
of the Totalizer 1 to 3
submenu:
• Volume flow
• Corrected volume flow
• Corrected methane volume
flow
*
• Mass flow
• Energy flow
*
Specify start value for totalizer.
Dependency
The unit of the selected
process variable is
specified for the totalizer
in the Unit totalizer
parameter (→ 85).
Signed floating-point
number
Country-specific:
• 0 m³
• 0 ft³
Reset all totalizers – Reset all totalizers to 0 and
start.
• Cancel
• Reset + totalize
Cancel
* Visibility depends on order options or device settings
11.6 Showing data logging
The Extended HistoROM application package must be enabled in the device (order
option) for the Data logging submenu to appear. This contains all the parameters for the
measured value history.
The measured value history is also accessible via the FieldCare plant asset
management tool → 49.